All solid high voltage fast switch
All solid high voltage fast switch
High voltage discharge switch is the most important part of high voltage pulse generator, which determines the main performance index of high voltage pulse power supply. With the support of national key R & D projects, pulse tech. has developed a series of all solid state high voltage fast switches. The all solid state high voltage fast switch provided by Pooles has the characteristics of fast rising edge and high repetition rate. Based on these fast switches, high voltage pulse power supply with different parameters and requirements can be easily established. It is widely used in transient characteristic test system, electromagnetic compatibility test instrument and many other fields. It can also be used for the establishment of scientific research system and the development of scientific instruments and devices Etc.
Maximum switching speed:1ns
Maximum pulse repetition rate:3MHz
Pulse width from 5ns to DC
Over voltage / over current / overheating protection
Transient characteristic test
EMC test equipment
Calibration of instruments and equipment
Establishment of scientific research system
Development of scientific instruments
Lightning test equipment
Establishment of high power electromagnetic environment
Application load type: capacitive load, resistive load, inductive load
Nanosecond switch leading edge
Peak current range: 10A ~ > 1ka
Working voltage range: 0 ~ 20kV
Switching speed: 1ns ~ 25ns
Pulse width range: 5ns ~ DC
Pulse repetition frequency: 1kHz ~ 3MHz
Protection type: over voltage / over current / overheating protection
Switch form: single switch, half bridge switch
It can provide more flexible customized development
Single switch seriesHalf bridge switch series
Model | Maximum operating voltage | Switching speed | Pulse width range | Maximum repetition rate | Average current | peak current |
SPS-C-2-05 | 2kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
SPS-C-2-10 | 2kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
SPS-C-2-20 | 2kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
SPS-C-3-05 | 3kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
SPS-C-3-10 | 3kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
SPS-C-3-20 | 3kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
SPS-C-4-05 | 4kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
SPS-C-4-10 | 4kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
SPS-C-4-20 | 4kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
SPS-C-4-30 | 4kV | 1ns | 10ns~DC | 100kHz | <30A | <80A |
SPS-C-5-05 | 5kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
SPS-C-5-10 | 5kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
SPS-C-5-20 | 5kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
SPS-C-5-30 | 5kV | 1ns | 10ns~DC | 100kHz | <30A | <80A |
SPS-C-5-40 | 5kV | 1ns | 10ns~DC | 100kHz | <40A | <100A |
SPS-S-5-20 | 5kV | 2ns | 10ns~DC | 3MHz | <20A | <100A |
Note: the combination of pulse width and repetition rate is limited by the average power; the value of switching speed is measured at 20% of the maximum working voltage.
Model | Maximum operating voltage | Switching speed | Pulse width range | Maximum repetition rate | Average current | peak current |
BPS-C-2-05 | 2kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
BPS-C-2-10 | 2kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
BPS-C-2-20 | 2kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
BPS-C-3-05 | 3kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
BPS-C-3-10 | 3kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
BPS-C-3-20 | 3kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
BPS-C-4-05 | 4kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
BPS-C-4-10 | 4kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
BPS-C-4-20 | 4kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
BPS-C-4-30 | 4kV | 1ns | 10ns~DC | 100kHz | <30A | <80A |
BPS-C-5-05 | 5kV | 1ns | 10ns~DC | 100kHz | <5A | <15A |
BPS-C-5-10 | 5kV | 1ns | 10ns~DC | 100kHz | <10A | <30A |
BPS-C-5-20 | 5kV | 1ns | 10ns~DC | 100kHz | <20A | <60A |
BPS-C-5-30 | 5kV | 1ns | 10ns~DC | 100kHz | <30A | <80A |
BPS-C-5-40 | 5kV | 1ns | 10ns~DC | 100kHz | <40A | <100A |
BPS-S-5-20 | 5kV | 2ns | 10ns~DC | 3MHz | <20A | <100A |
Note: the combination of pulse width and repetition rate is limited by the average power; the value of switching speed is measured at 20% of the maximum working voltage.